User manual forDATAMAN-848PRO2Extremely fast universal 8x 48-pindrive Stand-Alone concurrent multiprogrammingsystemInternal PC is driven by Microsoft
10SelftestWarning:Selftest can be run in engineering mode only.This mode is available only when external display, keyboard and mouse are connectedto D
11Technical specificationSpecification (DATAMAN-848PRO2 multiprogrammingsystem) 8x universal programming module (8x 48-pin DIL ZIF sockets and 8x ISP
12 target system supply voltage (range 2V..6V/250mA) ESD protection on each pin of ISP connector (IEC1000-4-2: 15kV air, 8kV contact) two output si
13 FPGA: FPGA: Microsemi(Actel): ProASIC3, IGLOO, Fusion, ProASICplus,SmartFusion FPGA: Lattice: MachXO, MachXO2, LatticeXP, LatticeXP2, ispXP
14 Microcontrollers NXP (Philips) ARM7: LPC2xxx, MPT6xx, PCD807xx, SAF7780xxxseries Microcontrollers NXP (Philips) ARM9: LPC31xx series Microcontro
15 Microcontrollers EM Microelectronic: 4 and 8 bit series Microcontrollers Microchip PICmicro: PIC10xxx, PIC12xxx, PIC16xxx, PIC17xxx,PIC18xxx, PI
16Programming speedDevice Size [bits] Operation TimeK8P6415UQB (parallel NOR Flash) 400100Hx16 (64 Mega) programming and verify 13 secMT29F1G08ABAEAW
17 count-down modeBuffer operations view/edit, find/replace fill/copy, move, byte swap, word/dword split checksum (byte, word) printFile load/sav
18Programming a deviceDATAMAN-848PRO2 can operate in two modes:Engineering mode for creating a projectProduction mode for mass productionEngineering m
19Make a project1. Connect external display, keyboard and mouse to PC connectors on back side ofprogrammer Turn on programmer.2. Run the control pro
2COPYRIGHT 2015Dataman Programmers LtdThis document is copyrighted by Dataman Programmers Ltd, United Kingdom. All rightsreserved. This document or
20Select DATAMAN-848PRO2, Site and then click on “Connect” button.4. Select site.Select desired DATAMAN-848PRO2 Site# and then click on “OK” button5.
216. Load data into buffer from file: click on icon.7. Set Device operation optionsSet desired operations for the device and then click on “OK” but
22Note: Menu Device operation options and <Alt+S> depend on the selecteddevice.9. Save project: click on and select destination folder, write a
23Checking if the sites are ready to be connected7. When first starting Stand-Alone multiprogramming system, or when errormessage “Programmer Sites no
24predefined operation is “Program device“, the caption of button Run will be “RunProgram“.18. Selected device operation including sub-operations tha
25SoftwareDetailed description of Graphics user interfacewith touch screenWait please screenWait please screen is displayed on standalone's built
26LCD main screenMain screen consists of following parts: Menu: File Device Programmer Options Help Table with information about programme
27Next serial valueWhen serialization is active, the panel displays current serialization mode andserialization number or label that will be used for
28When option 1 is selected, dialog with list of project files present in [Projects] folder willappear. User can select desired project and load the p
29When option 1 is selected, the dialog with list of project files at specified drive and folderwill appear. User can select desired drive, folder and
3Table of contentsIntroduction ...
30File / Switch to Engineering modeCommand is used to start PG4UW control program in Engineering mode. In this mode,user can use PG4UW software to sel
31Each Master operation can consist of a sequence of one or more partial operations, forexample Program device operation can consist of the following
32If search result is “No Programmers found”, please try to turn off Stand-Aloneprogrammer, by menu “File / Shut down computer”, turn off the power bu
33When Automatic YES! mode is On, programmer sites are scanning their device socketsafter device operation is completed. The control program can detec
34Menu OptionsOptions / Switch to Operator Mode... Switch to Administrator ModeProgram PG4UWMC is set by default to Administrator Mode. It means, no o
35project load. To enable Load project command again, Administrator Mode ofPG4UWMC must be entered.To switch program from Operator Mode back to Admini
36Log file...Log file settings screen looks as following:Log file is text file containing information about PG4UWMC control program operationflow, whi
37 < log_file_name><-yyyy-mmm-dd>.<log_file_extension>The new part representing the date consists of yyyy - year, mmm - month and
38Display backlight allows user to control backlight intensity.Border style offers options to set color for unused part of LCD screen (left andright b
39Options / Statistics...Command displays dialog “Statistics”. Statistics gives the information about actualcount of device operations, which were pro
4IntroductionDATAMAN-848PRO2 is extremely fast universal 8x 48-pindrive Stand-Aloneconcurrent multiprogramming system designed for high volume product
40Options / View Log...Command displays content of current Log window. At top right corner is the button [x],which is used for closing the Log window
41Help / Update software...This important menu command allows users to make software updates. After selectingthis item, program will display question
42Welcome screen is displayed on standalone's build-in LCD screen after successfulstarting of standalone control software. The screen can be also
43Remote controlAdministering of DATAMAN-848PRO2 Stand-Alone multiprogramming system isperformed through Microsoft “Remote Desktop Connection”. Remote
44Because work with remote desktop is similar to working on local station, pleasecontinue to read chapter “Local administration”.Local administrationF
45System restoreSystem restore performs refreshing of programmer operating system to state as it wasshipped from factory.Before operating system recov
46Recovery starts formatting of disks, and installation of control program.When first part of recovery finish, press any key, and system will be resta
47Troubleshooting and warrantyTroubleshootingWe really want you to enjoy our product. Nevertheless, problems can occur. In suchcases please follow the
48Hardware warningsClass A ITE noticeDevice described in this manual is class A products. In domesticenvironment this product may cause radio interfer
49MaintenanceWe recommend following the instructions and precautions herein to achieve highreliability of the programmer for a long period of time.The
5that new device support requires the software to be updated and (if necessary) simplepackage converter (programming adapter), therefore the ownership
50Warranty termsThe manufacturer, Dataman Programmers Ltd, gives a guarantee on failure-freeoperating of the DATAMAN-848PRO2 programmer and all its pa
6Advanced design of the DATAMAN-848PRO2 Stand-Alone multiprogramming system,including protective circuits, original brand components, and careful manu
7Manipulation with the programmed deviceAfter the selection of desired device for your work, you can insert it into the open ZIFsocket (lever is up) a
8Description of ISP connector1234567891011121314151617181920Front view at ISP connector.H/L/read driverRA1pin of ISPconnectorRA2RA3Pull-up/Pull-downRe
9Comment to above picture:picture C) Connection of pins 15 and 16 when are configured as logical signalneeded for ISP programmingpictures D) E) When